Water Purifier LB-47WP delivers a water production rate of 250 litres per hour with a flow speed of 4.3 L/min. It features an operating water temperature range of 5 to 40 °C. Equipped with an inlet water pressure range of 0.15 to 0.5 MPa and capable of handling feed water with TDS below 200 ppm. Our Water Purifier Provides RO water parameters, DI water parameters compliant with ASTM Type II grade water, and ultrapure water parameters meeting ASTM Type I grade water standards.
$ 7140
Download CatalogSpecifications
| Water Rate | 250 L/h |
| Flow Speed | 4.3 L/min |
| Water Temperature | 5 to 40℃ |
| Inlet Water Pressure | 0.15 to .05 mpa |
| Total Dissolved Solids | <200 ppm |
| RO Water Ion Rejection Rate | 97% to 99% |
| RO Water Organic matter rejection rate | >99% when MW>200 Dalton |
| RO Water Particle and bacterial rejection | >99% |
| DI Water Resistivity (25℃) | 10 to 16 M Ω. cm at 25℃ |
| DI Water Conductivity | <0.1 µ S/cm |
| UP Water Resistivity (25℃) | 18.25 M Ω. cm at 25℃ |
| UP Water Heavy metal ion | <0.01 ppb |
| UP Water Total organic carbon (TOC) | <10 ppb |
| Particulate matter (>0.1microns) | <1/ml |
| Power Consumption | 240 W |
| Power Supply | 100 to 240 V/50 to 60 Hz, |
| Water Tank Dimension | 390 × 390 × 870 mm |
| Water Tank Packaging Dimension | 450 × 450 × 1100 mm |
| Machine Dimension | 600 × 600 × 1200 mm |
| Machine Packaging Dimension | 780 × 700 × 1460 mm |
| Water Tank Net Weight | 15 kg |
| Water Tank Gross Weight | 28 kg |
| Machine Net Weight | 110 kg |
| Machine Gross Weight | 130 kg |
Features
Fully Automatic Microcomputer Control
Easy Filter Replacement & Maintenance
Electrical And Water Channel Separation
Real-Time Operating Status Display
Floor-Standing Design
Movable And Fixed Support Feet
Standard Accessories
100 L Pressure Water Storage Tank
TDS Pen
Optional Accessories
S. No | Accessory Name | Quantity |
1 | 20’’ 5 μm PP cotton | 1 pc |
2 | 20’’ Refined activated carbon | 2 pcs |
3 | 600 GPD RO membrane | 3 pcs |
4 | 25L ultra purified tank | 1 pc |
5 | 12’’ ultra purification column | 2 pcs |
6 | 0.2um terminal filter | 1 pc |
Applications
Water Purifier is widely used for laboratory glassware washing, reagent and buffer preparation, microbiological media preparation, analytical instruments such as HPLC, IC and GC, and general laboratory research applications.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Output (25°C) | 15 L/H |
| Flow Rate | Up to 2 L/min (with pressure tank) |
| Pure Water Outlet | 2; reverse osmosis and deionized water |
| Deionized Water Resistivity | 16 - 18.2 MΩ.cm |
| Deionized Water Bacteria | < 0.1 cfu/ml |
| Output (25°C) | 24 L/H |
| Flow Rate | Up to 2 L/mint (with tank) |
| Pure Water Outlet | 2; deionized water and ultrapure water |
| Ultrapure Water Resistivity | 18.2 MΩ.cm |
| TOC | <3 ppb |
| Output (25°C) | 2 L/H (less output with UF cartridge) |
| Pure Water Outlet | 2; deionized water and ultrapure water |
| Ultrapure Water Resistivity | 18.2 MΩ.cm |
| TOC | <10 ppb |
| Ultrapure Water Bacteria | <0.1 cfu/ml |
| Output (25°C) | 15 L/H |
| Flow Rate | Up to 2 L/min (with pressure tank) |
| Pure Water Outlet | 2; reverse osmosis and ultrapure water |
| Ultrapure Water Resistivity | 18.2 MΩ.cm |
| TOC | <3 ppb |
| Output (25°C) | 2 L/H (less output with UF cartridge) |
| Pure Water Outlet | 2; deionized water and ultrapure water |
| Ultrapure Water Resistivity | 18.2 MΩ.cm |
| TOC | <3 ppb |
| Ultrapure Water Bacteria | <0.1 cfu/ml |
| Output (25°C) | 15 L/H |
| Flow Rate | Up to 2 L/min (with pressure tank) |
| Pure Water Outlet | 2; reverse osmosis and deionized water |
| Deionized Water Resistivity | 18.2 MΩ.cm |
| Deionized Water Bacteria | < 0.1 cfu/ml |
| Output (25°C) | 12 L/H |
| Flow Rate | Up to 2 L/mint (with tank) |
| Pure Water Outlet | 2; deionized water and ultrapure water |
| Ultrapure Water Resistivity | 18.2 MΩ.cm |
| TOC | <3 ppb |
| Output (25°C) | 15 L/h |
| Flow Rate | Up to 2 L/min (with pressure tank) |
| Pure Water Outlet | 2 (Manual and automatic control) |
| Deionized Water Resistivity | 13 to 16uΩ-cm |
| Deionized Water Bacteria | < 0.1 cfu/ml |
| Output (25°C) | 15 L/H |
| Flow Rate | Up to 2 L/min (with pressure tank) |
| Pure Water Outlet | 2; reverse osmosis and ultrapure water |
| Ultrapure Water Resistivity | 18.2 MΩ.cm |
| TOC | <3 ppb |
| Output | 250 L/h |
| Flow Rate | 4.3 L/min(with pressure barrel) |
| Feed Water | Urban tap water with TDS < 200ppm |
| Inlet Water Temperature Range | 5 to 40℃ |
| Inlet Water Pressure Range | 0.15 to 0.5mpa |
| Output (25°C) | 12 L/H |
| Flow Rate | Up to 2 L/mint (with tank) |
| Pure Water Outlet | 2; deionized water and ultrapure water |
| Ultrapure Water Resistivity | 18.2 MΩ.cm |
| TOC | <10 ppb |
| Output (25°C) | 15 L/H |
| Flow Rate | Up to 2 L/min (with pressure tank) |
| Pure Water Outlet | 2; reverse osmosis and ultrapure water |
| Ultrapure Water Resistivity | 18.2 MΩ.cm |
| TOC | <10 ppb |
| Output (25°C) | 24 L/H |
| Flow Rate | Up to 2 L/mint (with tank) |
| Pure Water Outlet | 2; deionized water and ultrapure water |
| Ultrapure Water Resistivity | 18.2 MΩ.cm |
| TOC | <10 ppb |
| Output (25°C) | 24 L/H |
| Flow Rate | Up to 2 L/mint (with tank) |
| Pure Water Outlet | 2; deionized water and ultrapure water |
| Ultrapure Water Resistivity | 18.2 MΩ.cm |
| TOC | <3 ppb |
| Output (25°C) | 2 L/H (less output with UF cartridge) |
| Pure Water Outlet | 2; deionized water and ultrapure water |
| Ultrapure Water Resistivity | 18.2 MΩ.cm |
| TOC | <3 ppb |
| Ultrapure Water Bacteria | <0.1 cfu/ml |