Portable Turbidity Meter LB-10PTM

Portable Turbidity Meter LB-10PTM

Portable turbidity meter LB-10PTM is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. Automatic power off post thirty minutes of non-use prolongs battery life. It measures the turbidity of water.

Buy Now Download Catalog

Specifications

Measurement range 0 ~ 100
0 ~ 200
Calibration point 4
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Error ± 6 % ( ± 2 % F.S )
Battery power 1.5 V
Power supply AC 220 V/50 Hz
DC 7.5 V/0.2 A
Dimensions 210 × 75 × 70 mm
Weight 0.5 kg

Features

  • LED screen displays measurements and results
  • Test data storage ( 10 groups )
  • Dust and waterproof structure
  • Semi-automatic calibration
  • Auto power off ( after 30 minutes )

Applications

Used in wastewater treatments, laboratories, aquaculture, agriculture, research institutes, food and beverage industry, etc.

Our Team Of Experts Will Promptly Address Your Inquiry.

What our customers say

Jeadelyn . logo

7 months ago

Monir Hossain logo

4 years ago

Remon logo

5 months ago

Shareef Uddin logo

1 year ago

Khushboo Sahani logo

4 months ago

Add a review

Portable Turbidity Meter

Portable Turbidity Meter : Portable Turbidity Meter LB-14PTM
Measurement range 0 ~ 100
100 ~ 1000
Calibration point 7
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Portable Turbidity Meter : Portable Turbidity Meter LB-15PTM
Measurement range 0 ~ 200
Calibration point 2
Minimum value 0.1
Repeatability ≤ 1 %
Portable Turbidity Meter : Portable Turbidity Meter LB-13PTM
Measurement range 0 ~ 100
100 ~ 800
Calibration point 6
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Portable Turbidity Meter : Portable Turbidity Meter LB-19PTM
Measurement Range 0 to 1100 NTU
0 to 275 EBC
0 to 9999 ASBC
Resolution 0.01 (0 to 99 NTU)
0.1 (100 to 999 NTU)
1 (1000 to 1100 NTU)
Accuracy ± 2% of reading (0 to 500 NTU)
± 3% of reading (501 to 1100 NTU)
Measurement Principal ISO 7027 nephelometric method (90°)
Portable Turbidity Meter : Portable Turbidity Meter LB-18PTM
Measurement range 0 ~ 20
0 ~ 200
Calibration point
Minimum value 0.01
0.1
Repeatability ≤ 1 %
Portable Turbidity Meter : Portable Turbidity Meter LB-16PTM
Measurement range 0 ~ 1000
Calibration point 7
Minimum value 0.1
Repeatability ≤ 1 %
Portable Turbidity Meter : Portable Turbidity Meter LB-17PTM
Measurement range 0 ~ 20
Calibration point
Minimum value 0.01
Repeatability ≤ 1 %
Portable Turbidity Meter : Portable Turbidity Meter LB-12PTM
Measurement range 0 ~ 100
100 ~ 500
Calibration point 6
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Portable Turbidity Meter : Portable Turbidity Meter LB-11PTM
Measurement range 0 ~ 100
100 ~ 400
Calibration point 5
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %

Our handheld salinity meters are portable devices designed for on-the-spot measurement of salinity levels in liquids, particularly in aquatic environments. These compact instruments typically use conductivity or refractometry principles to assess the concentration of dissolved salts in water. Featuring a user-friendly interface and a digital display, handheld salinity meters provide quick and accurate readings, making them invaluable tools for fieldwork, aquaculture, and environmental monitoring. The meters often offer versatility by allowing users to switch between practical salinity units and other measurement units. With their portability and ease of use, handheld salinity meters contribute to efficient water quality assessment in diverse applications, ensuring the optimal conditions for aquatic ecosystems, research, and industrial processes.

Measurement range 0 ~ 2500 mg/L
Temperature 0 °C ~ 50 °C
Accuracy ( at 0.1 °C ) ± 2 mg/L
Resolution 1 mg/L
Measurement range 0 ~ 9999 mg/L
Temperature 0 °C ~ 50 °C
Accuracy ( at 0.1 °C ) ± 2 mg/L
Resolution 1 mg/L
Measurement range 0 ~ 300 %
Temperature 0 °C ~ 50 °C
Accuracy ( at 0.1 °C ) ± 0.2 %
Resolution 0.02

Our Pocket TDS (Total Dissolved Solids) Meters are compact handheld devices designed for quick and convenient measurement of the concentration of dissolved solids in water. These meters typically use conductivity measurements to estimate TDS levels, providing users with valuable insights into water quality. With their portable design, digital displays, and straightforward operation, pocket TDS meters are widely used in applications such as water testing, aquarium maintenance, and hydroponics. They offer a practical and efficient way to assess the mineral content of water, ensuring its suitability for various purposes and providing essential information for maintaining optimal conditions in diverse environments.

TDS measuring range 0 ~ 2500 ppm
EC measuring range
Temperature range 0 °C ~ 50 °C
Resolution 2 ppm
TDS measuring range 0 ~ 5000 ppm
EC measuring range 0 ~ 999 µs/cm
Temperature range 0.1 °C ~ 80 °C
Resolution
TDS measuring range 0 ~ 9999 ppm
EC measuring range
Temperature range 0 °C ~ 50 °C
Resolution 10 ppm

Labotronics Ratio Turbidimeter is an analytical instrument specifically designed for measuring the turbidity of liquid samples by employing a ratio turbidimetry technique. This method involves the measurement of scattered light at two different angles, typically 90 and 180 degrees, to enhance accuracy in turbidity readings. The instrument uses a dual detector system to minimize interferences and improve sensitivity, ensuring precise and reliable turbidity measurements. Our ratio turbidimeters are commonly employed in water treatment facilities, environmental monitoring, and industrial processes where accurate turbidity assessments are crucial for quality control and regulatory compliance.

Measurement range 0.005 ~ 50.0 NTU 1 ~ 200 NTU
Allowable error of indication ≤ ± 8 %
Receiving element Silicon photocell
Light source Tungsten halogen lamp 6 V, 10 W
Measurement range 0.005 ~ 50.0 NTU 1 ~ 200 NTU 201 ~2000 NTU
Allowable error of indication 0 ~ 200 NTU: ≤ ± 8 % 201 ~ 200 NTU: ≤ ± 6 %
Receiving element Silicon photocell
Light source Tungsten halogen lamp 6 V, 10 W
Measurement range 0.005 ~ 50.0 NTU 1 ~ 200 NTU 201 ~2000 NTU 2001~4000 NTU
Allowable error of indication ≤ ± 6 %
Receiving element Silicon photocell
Light source Tungsten halogen lamp 6 V, 10 W

Our ORP (Oxidation-Reduction Potential) Pocket Meters are compact, handheld devices designed for convenient on-the-go measurement of the oxidative or reducing ability of a solution. Utilizing an electrode system, these meters assess the electron activity in the liquid, providing a quick indication of its redox potential. Commonly used in water quality testing, aquaculture, and industrial processes, ORP pocket meters are valuable tools for assessing the overall health and stability of a solution. With a portable design, digital display, and user-friendly controls, these meters offer flexibility in monitoring and optimizing oxidative/reductive conditions in various settings, contributing to the efficient management of water quality, chemical processes, and environmental conditions.

Measuring range ± 1999 mV
Accuracy ± 5 mV
Temperature 0 °C ~ 50 °C
Resolution
Measuring range -1200 mV ~ 1200 mV
Accuracy ± 2 mV
Temperature 0 °C ~ 50 °C
Resolution 1 mV

Labotronics Benchtop Turbidity Meter is a laboratory instrument designed to measure the cloudiness or turbidity of a liquid sample. Typically used in environmental monitoring, water treatment plants, and research laboratories, these meters utilize optical sensors to quantify the amount of suspended particles or colloids in the liquid. The benchtop design ensures stability during measurements, and the meters often feature a digital display for convenient and accurate readings. Our benchtop turbidity meter is an essential tool for researchers and professionals working in fields where precise turbidity measurements are necessary for quality control and compliance with regulatory standards.

Measurement range 0 ~ 100 100 ~ 200
Minimum value 0.01 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Type Benchtop
Principle method Nephelometric principle with 90° detection
Measuring Range 0 to 20, 20 to 200, and 200 to 1000 NTU
Auto-ranging 0 to 1000 NTUs
Measurement range 0 ~ 800
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Measurement range 0 ~ 1000
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
WhatsApp
×

Get Quotation

Follow Us