Measurement Range

Model No

Turbidity Range

Resolution

Portable Turbidity Meter LB-10PTM

Measurement range 0 ~ 100
0 ~ 200
Calibration point 4
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Error ± 6 % ( ± 2 % F.S )

$ 1200

Portable Turbidity Meter LB-11PTM

Measurement range 0 ~ 100
100 ~ 400
Calibration point 5
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Error ± 6 % ( ± 2 % F.S )

$ 1225

Portable Turbidity Meter LB-12PTM

Measurement range 0 to 100
100 to 500
Calibration point 6
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Error ± 6 % ( ± 2 % F.S )

$ 1275

Portable Turbidity Meter LB-13PTM
Measurement range 0 ~ 100
100 ~ 800
Calibration point 6
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Error ± 6 % ( ± 2 % F.S )

$ 1337.5

Portable Turbidity Meter LB-14PTM
Measurement range 0 ~ 100
100 ~ 1000
Calibration point 7
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Error ± 6 % ( ± 2 % F.S )

$ 1412.5

Portable Turbidity Meter LB-15PTM

Measurement range 0 ~ 200
Calibration point 2
Minimum value 0.1
Repeatability ≤ 1 %
Error ± 8 % ( ± 2.5 % F.S )

$ 1100

Portable Turbidity Meter LB-16PTM

Measurement range 0 ~ 1000
Calibration point 7
Minimum value 0.1
Repeatability ≤ 1 %
Error ± 8 % ( ± 2.5 % F.S )

$ 1187.5

Portable Turbidity Meter LB-17PTM

Measurement range 0 ~ 20
Minimum value 0.01
Repeatability ≤ 1 %
Error ± 8 % ( ± 2.5 % F.S )
Battery power 1.5 V

$ 1125

Portable Turbidity Meter LB-18PTM
Measurement range 0 ~ 20
0 ~ 200
Minimum value 0.01
0.1
Repeatability ≤ 1 %
Error ± 8 % ( ± 2.5 % F.S )
Battery power 1.5 V

$ 1125

Portable Turbidity Meter LB-19PTM
Measurement Range 0 to 1100 NTU
0 to 275 EBC
0 to 9999 ASBC
Resolution 0.01 (0 to 99 NTU)
0.1 (100 to 999 NTU)
1 (1000 to 1100 NTU)
Accuracy ± 2% of reading (0 to 500 NTU)
± 3% of reading (501 to 1100 NTU)
Measurement Principal ISO 7027 nephelometric method (90°)
Sample Volume 30 mL

$ 1387.5

Portable Turbidity Meter LB-20PTM

Model No LB-20PTM
Measuring Range 0 to 1000 NTU (Turbidity); 0 to 1000 mg/L (Total Suspended Solids)
Indication Error ±0.3 NTU or ±8 % (Turbidity); ±0.3 mg/L or ±8 % (Total Suspended Solids)
Repeatability <10 NTU: ≤±0.1 NTU; >10 NTU: ≤±1 % (Turbidity); <10 mg/L: ≤±0.1 mg/L; >10 mg/L: ≤±1 % (Total Suspended Solids)
Calibration Range Up to 8-point (Turbidity); One-point (Total Suspended Solids)

$ 1970

Portable Turbidity Meter LB-21PTM

Turbidity Range 0 to 20 NTU
0 to 1000 NTU
Operating Temperature Range 5 to 40℃
Storage Temperature Range -10 to 55℃
Humidity Range 0 to 80% RH
Indication Error ±0.1 NTU or ±5% NTU (0 to 20 NTU Turbidity)
±0.3 NTU or ±8% NTU (0 to 1000 NTU Turbidity)

$ 1770

Still have questions?

If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!


0
×

Ask Quote

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Copyright © Labotronics Scientific 2026