Portable Turbidity Meter LB-15PTM

Portable Turbidity Meter LB-15PTM

Portable turbidity meter LB-15PTM is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. Automatic power off post thirty minutes of non-use prolongs battery life. It measures the turbidity of water.

Buy Now Download Catalog

Specifications

Measurement range 0 ~ 200
Calibration point 2
Minimum value 0.1
Repeatability ≤ 1 %
Error ± 8 % ( ± 2.5 % F.S )
Battery power 1.5 V
Power supply AC 220 V/50 Hz
DC 7.5 V/0.2 A
Dimensions 210 × 75 × 70 mm
Weight 0.5 kg

Features

  • LED screen displays measurements and results
  • Test data storage ( 10 groups )
  • Dust and waterproof structure
  • Semi-automatic calibration
  • Auto power off ( after 30 minutes )

Applications

Used in wastewater treatments, laboratories, aquaculture, agriculture, research institutes, food and beverage industry, etc.

Our Team Of Experts Will Promptly Address Your Inquiry.

What our customers say

Add a review

Portable Turbidity Meter

Portable Turbidity Meter : Portable Turbidity Meter LB-12PTM
Measurement range 0 ~ 100
100 ~ 500
Calibration point 6
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Portable Turbidity Meter : Portable Turbidity Meter LB-18PTM
Measurement range 0 ~ 20
0 ~ 200
Calibration point
Minimum value 0.01
0.1
Repeatability ≤ 1 %
Portable Turbidity Meter : Portable Turbidity Meter LB-16PTM
Measurement range 0 ~ 1000
Calibration point 7
Minimum value 0.1
Repeatability ≤ 1 %
Portable Turbidity Meter : Portable Turbidity Meter LB-14PTM
Measurement range 0 ~ 100
100 ~ 1000
Calibration point 7
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Portable Turbidity Meter : Portable Turbidity Meter LB-11PTM
Measurement range 0 ~ 100
100 ~ 400
Calibration point 5
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Portable Turbidity Meter : Portable Turbidity Meter LB-17PTM
Measurement range 0 ~ 20
Calibration point
Minimum value 0.01
Repeatability ≤ 1 %
Portable Turbidity Meter : Portable Turbidity Meter LB-13PTM
Measurement range 0 ~ 100
100 ~ 800
Calibration point 6
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %
Portable Turbidity Meter : Portable Turbidity Meter LB-19PTM
Measurement Range 0 to 1100 NTU
0 to 275 EBC
0 to 9999 ASBC
Resolution 0.01 (0 to 99 NTU)
0.1 (100 to 999 NTU)
1 (1000 to 1100 NTU)
Accuracy ± 2% of reading (0 to 500 NTU)
± 3% of reading (501 to 1100 NTU)
Measurement Principal ISO 7027 nephelometric method (90°)
Portable Turbidity Meter : Portable Turbidity Meter LB-10PTM
Measurement range 0 ~ 100
0 ~ 200
Calibration point 4
Minimum value 0.01
0.1
Repeatability ≤ 0.5 %

Labotronics Ratio Turbidimeter is an analytical instrument specifically designed for measuring the turbidity of liquid samples by employing a ratio turbidimetry technique. This method involves the measurement of scattered light at two different angles, typically 90 and 180 degrees, to enhance accuracy in turbidity readings. The instrument uses a dual detector system to minimize interferences and improve sensitivity, ensuring precise and reliable turbidity measurements. Our ratio turbidimeters are commonly employed in water treatment facilities, environmental monitoring, and industrial processes where accurate turbidity assessments are crucial for quality control and regulatory compliance.

Measurement range 0.005 ~ 50.0 NTU 1 ~ 200 NTU
Allowable error of indication ≤ ± 8 %
Receiving element Silicon photocell
Light source Tungsten halogen lamp 6 V, 10 W
Measurement range 0.005 ~ 50.0 NTU 1 ~ 200 NTU 201 ~2000 NTU
Allowable error of indication 0 ~ 200 NTU: ≤ ± 8 % 201 ~ 200 NTU: ≤ ± 6 %
Receiving element Silicon photocell
Light source Tungsten halogen lamp 6 V, 10 W
Measurement range 0.005 ~ 50.0 NTU 1 ~ 200 NTU 201 ~2000 NTU 2001~4000 NTU
Allowable error of indication ≤ ± 6 %
Receiving element Silicon photocell
Light source Tungsten halogen lamp 6 V, 10 W

We provide a benchtop multiparameter meter is a versatile laboratory instrument designed to concurrently measure and display various physicochemical parameters in liquids. This compact device typically integrates probes for parameters such as pH, conductivity, dissolved oxygen, and temperature, providing a comprehensive analysis of liquid samples. Equipped with a user-friendly interface and a digital display, these meters offer efficient and precise data collection for research, quality control, and environmental monitoring purposes. Their benchtop design ensures stability and ease of use in laboratory settings, allowing scientists and researchers to streamline the measurement process and obtain valuable information about the composition and quality of liquids.

Temperature Parameters Range: -5 to 110 ºC, 23 to 230 ºF Unit: ºC, ºF Resolution: 0.1 Accuracy: ±0.2
Measurement Modes Reading Mode: Auto Read (Fast, Medium, Slow), Timed, Continuous Reading Prompts: Reading, Stable, Locked, Temp. Compensation: ATC, MTC
Parameters pH/ EC/ ISE/ Temp. (mV/ ORP/ pX/ Resistivity/ TDS /Sal.)
pH Range: -2.00 to 20.00 ph Resolution: 0.1, 0.01 pH Accuracy: ±0.01 pH Calibration Points: Up to 5 Standard Recognition: NIST, GB, and DIN buffers Slope Limit
COD Measuring Range 10 to 15000 mg/L
COD Detection Method Potassium Dichromate Method Potassium Permanganate method
COD Detection Lower Limit 10 mg/L
COD Digestion Temperature & Time 165 °C, 20 min
Measuring parameters pH/EC/ISE/Temperature (mV/ORP/pX/Resistivity/TDS/Salinity)
Measuring range pH: -2.000 to 20.000 pH mV/ORP: -2000.00 to 2000.00 mV pX range: -2.000 to 20.000 pX ISE: 1E-9 to 9.999E9 Conductivity: 0.000 µS/cm to 2000 mS/cm Resistivity: 5.00 Ω·cm to 100.00 MΩ·cm TDS: 0.000 to 1000 ppt Salinity: 0.0 to 80.0 ppt Temperature: -10 to 135°C, 14 to 275°F
Resolution pH: 0.1, 0.01, 0.001 pH mV/ORP: 0.1, 0.01 mV pX: 0.1, 0.01, 0.001 pX ISE: Up to 4 significant units Conductivity: 0.001 µS/cm Resistivity: 0.01 Ω·cm TDS: 0.001 ppm Salinity: 0.1 ppt Temperature: 0.1°C/°F
Accuracy pH: ±0.002 pH mV/ORP: ±0.1 mV or ±0.03% pX: ±0.002 pX ISE: ±0.3% Conductivity: ±0.5%FS Resistivity: ±0.5% FS TDS: ±0.5% Salinity: ±1 ppt Temperature: ±0.1 °C/°F

Our Pocket TDS (Total Dissolved Solids) Meters are compact handheld devices designed for quick and convenient measurement of the concentration of dissolved solids in water. These meters typically use conductivity measurements to estimate TDS levels, providing users with valuable insights into water quality. With their portable design, digital displays, and straightforward operation, pocket TDS meters are widely used in applications such as water testing, aquarium maintenance, and hydroponics. They offer a practical and efficient way to assess the mineral content of water, ensuring its suitability for various purposes and providing essential information for maintaining optimal conditions in diverse environments.

TDS measuring range 0 ~ 9999 ppm
EC measuring range
Temperature range 0 °C ~ 50 °C
Resolution 10 ppm
TDS measuring range 0 ~ 2500 ppm
EC measuring range
Temperature range 0 °C ~ 50 °C
Resolution 2 ppm
TDS measuring range 0 ~ 5000 ppm
EC measuring range 0 ~ 999 µs/cm
Temperature range 0.1 °C ~ 80 °C
Resolution

Labotronics Benchtop Turbidity Meter is a laboratory instrument designed to measure the cloudiness or turbidity of a liquid sample. Typically used in environmental monitoring, water treatment plants, and research laboratories, these meters utilize optical sensors to quantify the amount of suspended particles or colloids in the liquid. The benchtop design ensures stability during measurements, and the meters often feature a digital display for convenient and accurate readings. Our benchtop turbidity meter is an essential tool for researchers and professionals working in fields where precise turbidity measurements are necessary for quality control and compliance with regulatory standards.

Measurement range 0 ~ 800
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Measurement range 0 ~ 1000
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Measurement range 0 ~ 100 100 ~ 800
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Measurement range 0 ~ 100 100 ~ 400
Minimum value 0.01 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %

Our Benchtop Conductivity Meter is a compact and precision instrument used for measuring the electrical conductivity of liquids. Typically designed for laboratory or industrial settings, it consists of a control unit and a conductivity cell. The meter assesses the ability of a solution to conduct an electric current, providing valuable information about the solution's ionic content and purity. Our benchtop models offer accuracy and ease of use, often featuring digital displays, adjustable settings, and the capacity to measure a wide range of conductivity levels. Widely utilized in chemistry, environmental science, and quality control applications, these meters play a crucial role in ensuring the consistency and reliability of solutions in diverse industries.

Measuring range Conductivity: 0.00 µS/cm to 200 mS/cm TDS: 0.00 mg/L to 100 g/L
Resolution Conductivity: 0.01 µS/cm TDS: 0.01 mg/L
Accuracy ±1.0% FS
Conductivity reference temperature 25°C
Measuring range Conductivity: 0.000 µS/cm to 2000 mS/cm Resistivity: 5.00 Ω.cm to 100.00 MΩ.cm TDS: 0.000 to 1000 ppt Salinity: 0.00 to 8.00% Temperature: -10 to 135°C; 14 to 275°F
Resolution Conductivity: 0.001 µS/cm Resistivity: 0.01 Ω.cm TDS: 0.001 ppm Salinity: 0.01% Temperature: 0.1°C/°F
Accuracy Conductivity: ±0.5% FS Resistivity: ±0.5% FS TDS: ±0.5% FS Salinity: ±0.01% Temperature: ±0.1°C/°F
Conductivity calibration points Up to 5
Measurement range 0.0 ~ 199.9 µs/cm 200 µs/cm ~ 1999 µs/cm 2.0 µs/cm ~ 19.99 ms/cm 20 µs/cm ~ 199.9 ms/cm
Temperature compensation 10 °C ~ 50 °C ( manual )
Resolution 0.1/1µs/cm 0.01/0.1ms/cm
Accuracy ( electrode ) ± 1 % FS
Measurement range 0.0 ~ 2 × 105 µs/cm
Temperature compensation 15 °C ~ 35 °C ( manual )
Resolution
Accuracy ( electrode ) ± 1 % FS
WhatsApp
×