Portable turbidity meter LB-12PTM is a microprocessor-controlled unit with a backlight function that provides convenient operation in dark areas. Auto-ranging function enables accurate readings. Automatic power off post thirty minutes of non-use prolongs battery life. It measures the turbidity of water.
$ 1275
Download CatalogSpecifications
| Measurement range | 0 to 100 100 to 500 |
| Calibration point | 6 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 0.5 % |
| Error | ± 6 % ( ± 2 % F.S ) |
| Battery power | 1.5 V |
| Power supply | AC 220 V/50 Hz DC 7.5 V/0.2 A |
| Dimensions | 210 × 75 × 70 mm |
| Weight | 0.5 kg |
Features
Applications
Used in wastewater treatments, laboratories, aquaculture, agriculture, research institutes, food and beverage industry, etc.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Measurement range | 0 ~ 20 |
| Minimum value | 0.01 |
| Repeatability | ≤ 1 % |
| Error | ± 8 % ( ± 2.5 % F.S ) |
| Battery power | 1.5 V |
| Measurement range | 0 ~ 100 100 ~ 800 |
| Calibration point | 6 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 0.5 % |
| Error | ± 6 % ( ± 2 % F.S ) |
| Measurement range | 0 ~ 100 100 ~ 1000 |
| Calibration point | 7 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 0.5 % |
| Error | ± 6 % ( ± 2 % F.S ) |
| Measurement Range | 0 to 1100 NTU 0 to 275 EBC 0 to 9999 ASBC |
| Resolution | 0.01 (0 to 99 NTU) 0.1 (100 to 999 NTU) 1 (1000 to 1100 NTU) |
| Accuracy | ± 2% of reading (0 to 500 NTU) ± 3% of reading (501 to 1100 NTU) |
| Measurement Principal | ISO 7027 nephelometric method (90°) |
| Sample Volume | 30 mL |
| Turbidity Range | 0 to 20 NTU 0 to 1000 NTU |
| Operating Temperature Range | 5 to 40℃ |
| Storage Temperature Range | -10 to 55℃ |
| Humidity Range | 0 to 80% RH |
| Indication Error | ±0.1 NTU or ±5% NTU (0 to 20 NTU Turbidity) ±0.3 NTU or ±8% NTU (0 to 1000 NTU Turbidity) |
| Model No | LB-20PTM |
| Measuring Range | 0 to 1000 NTU (Turbidity); 0 to 1000 mg/L (Total Suspended Solids) |
| Indication Error | ±0.3 NTU or ±8 % (Turbidity); ±0.3 mg/L or ±8 % (Total Suspended Solids) |
| Repeatability | <10 NTU: ≤±0.1 NTU; >10 NTU: ≤±1 % (Turbidity); <10 mg/L: ≤±0.1 mg/L; >10 mg/L: ≤±1 % (Total Suspended Solids) |
| Calibration Range | Up to 8-point (Turbidity); One-point (Total Suspended Solids) |
| Measurement range | 0 ~ 1000 |
| Calibration point | 7 |
| Minimum value | 0.1 |
| Repeatability | ≤ 1 % |
| Error | ± 8 % ( ± 2.5 % F.S ) |
| Measurement range | 0 ~ 100 0 ~ 200 |
| Calibration point | 4 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 0.5 % |
| Error | ± 6 % ( ± 2 % F.S ) |
| Measurement range | 0 ~ 200 |
| Calibration point | 2 |
| Minimum value | 0.1 |
| Repeatability | ≤ 1 % |
| Error | ± 8 % ( ± 2.5 % F.S ) |
| Measurement range | 0 ~ 20 0 ~ 200 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 1 % |
| Error | ± 8 % ( ± 2.5 % F.S ) |
| Battery power | 1.5 V |
| Measurement range | 0 ~ 100 100 ~ 400 |
| Calibration point | 5 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 0.5 % |
| Error | ± 6 % ( ± 2 % F.S ) |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com