Labotronics Portable Turbidity Meter LB-22PTM offers turbidity measurement from 0 to 1100 NTU with ±2% accuracy up to 500 NTU and an infrared light source. The meter supports calibration with standard and user-defined values and includes an automatic power off function, while readings stored in memory can be reviewed later, so this handheld turbidity meter supports quick sample checks and easy record keeping.
$ 1572.5
Download CatalogSpecifications
| Measuring Range (NTU) | 0 to 1100 NTU |
| Accuracy | ± 2% (0 to 500 NTU) ± 3% (501 to 1100 NTU) |
| Resolution | 0.01 (0 to 100 NTU) 0.1 (100 to 999 NTU) 1 (999 to 1100 NTU) |
| Calibration Standards | 0.02, 10.00, 200, 500, 1000 or user-defined |
| Detector | Silicon Photodiode |
| Light Source Wavelength | 850 nm |
| Stray Light | < 0.02 NTU |
| Operating Temperature | 0℃ to 60℃ |
| Memory | Stores up to 100 data sets |
| Light Source Type | Infrared-emitting diode |
| Interface | USB |
| Power Off Function Type | Manual or Automatic |
| Auto Power Off Time Out | 15 minutes |
| Battery | 1 × 9 V |
| Sample Vial Dimension | 60 (Height) × 25 (Diameter) mm |
| Overall Dimension | 180 × 85 × 70 mm |
| Packaging Dimensions | 325 × 140 × 270 mm |
| Net Weight | 300 g |
| Gross Weight | 1.2 kg |
Features
Applications
Water Treatment → Turbidity checks on treated and raw water samples
Environmental Testing → Sample clarity monitoring in field testing
Food and Beverage → Clarity checks on liquid products
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Measurement range | 0 ~ 20 0 ~ 200 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 1 % |
| Error | ± 8 % ( ± 2.5 % F.S ) |
| Battery power | 1.5 V |
| Measurement Range | 0 to 1100 NTU 0 to 275 EBC 0 to 9999 ASBC |
| Resolution | 0.01 (0 to 99 NTU) 0.1 (100 to 999 NTU) 1 (1000 to 1100 NTU) |
| Accuracy | ± 2% of reading (0 to 500 NTU) ± 3% of reading (501 to 1100 NTU) |
| Measurement Principal | ISO 7027 nephelometric method (90°) |
| Sample Volume | 30 mL |
| Measurement range | 0 ~ 1000 |
| Calibration point | 7 |
| Minimum value | 0.1 |
| Repeatability | ≤ 1 % |
| Error | ± 8 % ( ± 2.5 % F.S ) |
| Measurement range | 0 ~ 100 100 ~ 400 |
| Calibration point | 5 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 0.5 % |
| Error | ± 6 % ( ± 2 % F.S ) |
| Measurement range | 0 ~ 200 |
| Calibration point | 2 |
| Minimum value | 0.1 |
| Repeatability | ≤ 1 % |
| Error | ± 8 % ( ± 2.5 % F.S ) |
| Measurement range | 0 ~ 100 0 ~ 200 |
| Calibration point | 4 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 0.5 % |
| Error | ± 6 % ( ± 2 % F.S ) |
| Measurement range | 0 ~ 100 100 ~ 800 |
| Calibration point | 6 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 0.5 % |
| Error | ± 6 % ( ± 2 % F.S ) |
| Model No | LB-20PTM |
| Measuring Range | 0 to 1000 NTU (Turbidity); 0 to 1000 mg/L (Total Suspended Solids) |
| Indication Error | ±0.3 NTU or ±8 % (Turbidity); ±0.3 mg/L or ±8 % (Total Suspended Solids) |
| Repeatability | <10 NTU: ≤±0.1 NTU; >10 NTU: ≤±1 % (Turbidity); <10 mg/L: ≤±0.1 mg/L; >10 mg/L: ≤±1 % (Total Suspended Solids) |
| Calibration Range | Up to 8-point (Turbidity); One-point (Total Suspended Solids) |
| Measurement range | 0 ~ 20 |
| Minimum value | 0.01 |
| Repeatability | ≤ 1 % |
| Error | ± 8 % ( ± 2.5 % F.S ) |
| Battery power | 1.5 V |
| Measurement range | 0 to 100 100 to 500 |
| Calibration point | 6 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 0.5 % |
| Error | ± 6 % ( ± 2 % F.S ) |
| Turbidity Range | 0 to 20 NTU 0 to 1000 NTU |
| Operating Temperature Range | 5 to 40℃ |
| Storage Temperature Range | -10 to 55℃ |
| Humidity Range | 0 to 80% RH |
| Indication Error | ±0.1 NTU or ±5% NTU (0 to 20 NTU Turbidity) ±0.3 NTU or ±8% NTU (0 to 1000 NTU Turbidity) |
| Measurement range | 0 ~ 100 100 ~ 1000 |
| Calibration point | 7 |
| Minimum value | 0.01 0.1 |
| Repeatability | ≤ 0.5 % |
| Error | ± 6 % ( ± 2 % F.S ) |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections
Best Seller
Quick Links
Copyright © Labotronics Scientific 2026