Temperature Test Chamber LB-37TTC operates within a maximum temperature range of -70 to +150°C and has a 1000L testing capacity. It ensures a cooling rate of 0.7 to 1.0°C/min, providing precise cooling. It utilizes a multi-leaf centrifugal fan for uniform temperature distribution. Our test chamber features a 7-inch touchscreen display for real-time monitoring of environmental testing conditions.
$ 17331.25
Download CatalogSpecifications
| Capacity | 1000L |
| Temperature Range | -70 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Heating Rate | 2.0 to 3.0°C/min |
| Cooling Rate | 0.7 to 1.0°C/min |
| Refrigerant | R404A/R23 |
| Refrigeration System | Unit cooling mode / Dual cooling mode |
| Heating System | NiCr heater, independent system |
| Circulation System | Single cycle, long axis, and stainless-steel multi-leaf type centrifuge fan |
| Display | 7-inch touch screen |
| Interior | Anti-corrosion SUS#304 mirror stainless steel |
| Exterior | Reinforced Steel plate with electrostatic spraying |
| Insulation | Superfine fiberglass wool/polyurethane foam |
| Power Supply | 220V 50/60Hz, 380V 50/60Hz or customized |
| Inner Dimension (W × D × H) | 1000 × 1000 × 1000 mm |
| Outer Dimension (W × D × H) | 1560 × 1610 × 2240 mm |
| Gross Weight | 790 kg |
Features
Applications
Temperature Test Chamber LB-37TTC is ideal for testing materials and products under extreme temperature conditions, ensuring performance and durability. It is widely used in electronics, automotive, aerospace, and pharmaceutical industries.
Frequently asked questions For Temperature Test Chamber
1. What is the Temperature Test Chamber LB-37TTC used for?
Labotronics LB-37TTC is designed for simulating controlled thermal conditions to evaluate product durability, stability, and reliability.
2. How does LB-37TTC ensure temperature consistency?
Our LB-37TTC chamber uses precision sensors and uniform airflow circulation to maintain stable and accurate test conditions.
3. Can the LB-37TTC run automated test programs?
Yes, it supports programmable test cycles for automated thermal cycling with minimal operator supervision.
4. How fast does LB-37TTC stabilize after temperature changes?
The LB-37TTC chamber's advanced heating and cooling system enables rapid stabilization, reducing downtime between tests.
5. Is the LB-37TTC suitable for long-duration testing?
Yes, LB-37TTC is engineered for continuous operation, making it reliable for extended test runs.
6. What is a Temperature Test Chamber used for?
A Temperature Test Chamber is used to simulate specific temperature conditions to test the durability, stability, and performance of products or materials in industries like electronics, automotive, aerospace, and pharmaceuticals.
7. How is temperature stability maintained during testing?
The chamber is equipped with precise control systems and insulated walls to ensure consistent temperature levels throughout the testing cycle.
8. How easy is it to operate the chamber with gloves on?
The user interface is designed to be glove-friendly, allowing operators to adjust settings and monitor tests without removing protective equipment.
9. Can the Labotronics test chamber handle both high and low temperatures?
Yes, Our Temperature Test Chambers can simulate a wide range of conditions, from extreme cold to high heat, making them ideal for various testing requirements.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Capacity | 50L |
| Temperature Range | -70 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 1000L |
| Temperature Range | -20 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 500L |
| Temperature Range | -20 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 50L |
| Temperature Range | 0 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 100L |
| Temperature Range | 0 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 250L |
| Temperature Range | -20 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 500L |
| Temperature Range | -40 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 150L |
| Temperature Range | 0 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 500L |
| Temperature Range | 0 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 800L |
| Temperature Range | -40 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 100L |
| Temperature Range | -20 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 1000L |
| Temperature Range | -40 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 100L |
| Temperature Range | -70 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 250L |
| Temperature Range | -70 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |
| Capacity | 1000L |
| Temperature Range | 0 to +150°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Temperature Uniformity | ≤ 2.0°C |