Fluid Refractometer LB-14FRR

Fluid Refractometer LB-14FRR

Fluid Refractometer LB-14FRR is equipped with automatic temperature compensation(ATC) that adjusts itself to correct temperature discrepancies during usage. Antifreeze, battery and cleaning fluids are detected. It features a vid and sharp reticle chart for easy and comfortable reading. Use ambient light and no batteries are needed.

Buy Now Download Catalog

Specifications

Measurement Range Ethylene Glycol: -50°C to 0 °C
Propylene: -50°C to 0 °C
C: -40°C to 0 °C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 1°C
Propylene: 1°C
C: 5 °C
Battery Fluids: 0.01sg
Accuracy Ethylene Glycol: ± 1 °C
Propylene Glycol: ± 1 °C
C: ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm
Weight 165 g

Features

  • Manual calibration (mini-screw driver provided)
  • Aluminum construction(Heavy-duty and lightweight)
  • Easy to focus and calibrate
  • Cushioned with soft & comfortable non-slip rubber
  • Extremely easy-to-use and calibrate

Applications

Fluid Refractometer LB-14FRR is used to test the concentration of ethylene glycol or propylene glycol in antifreeze liquids

Request Quotation

Fluid Refractometer

Measurement Range Ethylene Glycol: -60°C to 0°C (0 to 66.6 %)
Propylene Glycol: -50°C to 0°C (0 to 62.4 %)
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 5°C
Propylene Glycol: 5°C
Battery Fluids: 0.01 sg
Accuracy Ethylene Glycol: ± 5°C
Propylene Glycol: ± 5°C
Battery Fluids: ± 0.01 sg
Dimension (Length) 200 mm
Measurement Range Urea: 30% to 35%
Ethylene Glycol: -50°C to 0°C
Propylene Glycol: -50°C to 0°C
Cleaning Fluids: -40°C to 10°C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Urea: 0.5°C
Ethylene Glycol: 5°C
Propylene Glycol: 5°C
Cleaning Fluids: 5°C
Battery Fluids: 0.01 sg
Accuracy Urea: ± 0.5°C
Ethylene Glycol: ± 5°C
Propylene Glycol: ± 5°C
Cleaning Fluids: ± 5°C
Battery Fluids: ± 0.01 sg
Dimension (Length) 200 mm
Measurement Range Ethylene Glycol: - 60 °F to 32 °F/-50°C to 0 °C
Propylene: - 60°F to 32 °F /-50°C to 0 °C
Battery Fluids: 1.10-1.40 sg
Minimum Division Ethylene Glycol: 10°F/ 5°C
Propylene: 10°F/ 5°C
Battery Fluids: 0.01sg
Accuracy Ethylene Glycol: ± 10 °F/ ± 5 °C
Propylene Glycol: ± 10 °F/ ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm
Measurement Range Density: 0 to 100%
Ethylene Glycol: -60°C to 0 °C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Density: 0.05
Ethylene Glycol: 5 °C
Battery Fluids: 0.01sg
Accuracy Density: ± 5 %
Ethylene Glycol: ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm
Measurement Range Ethylene Glycol: -50°C to 0°C
Propylene Glycol: -50°C to 0°C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 1°C
Propylene Glycol: 1°C
Battery Fluids: 0.01 sg
Accuracy Ethylene Glycol: ± 1°C
Propylene Glycol: ± 1°C
Battery Fluids: ± 0.01 sg
Dimension (Length) 200 mm
Measurement Range Ethylene Glycol: -50°C to 0 °C
Propylene: -50°C to 0 °C
C: -40°C to 0 °C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 1°C
Propylene: 1°C
C: 5 °C
Battery Fluids: 0.01sg
Accuracy Ethylene Glycol: ± 1 °C
Propylene Glycol: ± 1 °C
C: ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm
WhatsApp
×