Fluid Refractometer LB-16FRR

Fluid Refractometer LB-16FRR

Fluid Refractometer LB-16FRR provides accurate readings with automatic temperature compensation. It measures antifreeze, battery fluids, and cleaning solutions with precision. It features a vivid and sharp reticle chart for easy and comfortable reading. Our refractometer uses ambient light for operation, eliminating the need for batteries.

$ 987.5

Download Catalog

Specifications

Measurement Range Density: 0 to 100%
Ethylene Glycol: -60°C to 0 °C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Density: 0.05
Ethylene Glycol: 5 °C
Battery Fluids: 0.01sg
Accuracy Density: ± 5 %
Ethylene Glycol: ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm
Weight 165 g

Features

  • Manual calibration with a mini screwdriver
  • Durable and lightweight aluminum construction
  • Easy to focus and calibrate
  • Soft, non-slip rubber grip
  • User-friendly and easy to use

Applications

Fluid Refractometer LB-16FRR is used for measuring antifreeze, battery fluids, and cleaning solutions. It is ideal for automotive, battery maintenance, and industrial cleaning.

Get Quote

Fluid Refractometer

Measurement Range Ethylene Glycol: -50°C to 0 °C
Propylene: -50°C to 0 °C
C: -40°C to 0 °C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 1°C
Propylene: 1°C
C: 5 °C
Battery Fluids: 0.01sg
Accuracy Ethylene Glycol: ± 1 °C
Propylene Glycol: ± 1 °C
C: ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm
Measurement Range Ethylene Glycol: -50°C to 0°C
Propylene Glycol: -50°C to 0°C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 1°C
Propylene Glycol: 1°C
Battery Fluids: 0.01 sg
Accuracy Ethylene Glycol: ± 1°C
Propylene Glycol: ± 1°C
Battery Fluids: ± 0.01 sg
Dimension (Length) 200 mm
Measurement Range Urea: 30% to 35%
Ethylene Glycol: -50°C to 0°C
Propylene Glycol: -50°C to 0°C
Cleaning Fluids: -40°C to 10°C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Urea: 0.5°C
Ethylene Glycol: 5°C
Propylene Glycol: 5°C
Cleaning Fluids: 5°C
Battery Fluids: 0.01 sg
Accuracy Urea: ± 0.5°C
Ethylene Glycol: ± 5°C
Propylene Glycol: ± 5°C
Cleaning Fluids: ± 5°C
Battery Fluids: ± 0.01 sg
Dimension (Length) 200 mm
Measurement Range Ethylene Glycol: -50°C to 0 °C
Propylene: -50°C to 0 °C
C: -40°C to 0 °C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 1°C
Propylene: 1°C
C: 5 °C
Battery Fluids: 0.01sg
Accuracy Ethylene Glycol: ± 1 °C
Propylene Glycol: ± 1 °C
C: ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm
Measurement Range Ethylene Glycol: -60°C to 0°C (0 to 66.6 %)
Propylene Glycol: -50°C to 0°C (0 to 62.4 %)
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 5°C
Propylene Glycol: 5°C
Battery Fluids: 0.01 sg
Accuracy Ethylene Glycol: ± 5°C
Propylene Glycol: ± 5°C
Battery Fluids: ± 0.01 sg
Dimension (Length) 200 mm
Measurement Range Ethylene Glycol: - 60 °F to 32 °F/-50°C to 0 °C
Propylene: - 60°F to 32 °F /-50°C to 0 °C
Battery Fluids: 1.10-1.40 sg
Minimum Division Ethylene Glycol: 10°F/ 5°C
Propylene: 10°F/ 5°C
Battery Fluids: 0.01sg
Accuracy Ethylene Glycol: ± 10 °F/ ± 5 °C
Propylene Glycol: ± 10 °F/ ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm