Sample Concentrator LB-14SC operates at a temperature range of 0 °C to 160 °C for efficient solvent evaporation. It is equipped with PID fuzzy control for stable and precise temperature regulation. It provides a nitrogen flow rate of 15 L/min, ensuring uniform sample processing. Our sample concentrator includes a microprocessor control for accurate and reliable operation.
$ 1462.5
Download CatalogSpecifications
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.02Mpa (Gas needle≤16pcs) 0.05Mpa (Gas needle>16pcs) |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5℃ to 160℃ |
| Temperature Accuracy | ≤±0.5℃ (at 40℃) ≤±1℃ (at 120℃) |
| Temperature Uniformity | ≤±0.5℃ |
| Display Accuracy | 0.1 °C |
| Heating Time | ≤ 15 mins (25 °C to 160 °C) |
| Timing Range | 1min to 99mins 59secs or Continuous (∞) |
| Maximum Vertical Movement | 200 mm |
| Power Consumption | 300 W |
| Power Supply | AC220/110V, 50/60Hz |
| Dimensions (W × D × H) | 260 × 220 × 450 mm |
| Weight | 7 kg |
Features
Adjustable gas needle pressure
Automatic fault detection
Over-temperature protection
Easy block replacement
Temperature deviation calibration
Optional Accessories
Flow Control Valve × 1 pc
Applications
Sample Concentrator LB-14SC is used in food testing, environmental monitoring, and pharmaceutical research facilities. It delivers rapid, oxygen-free solvent evaporation for accurate sample preparation.
Optional Blocks
Block No | Block Capacity |
B1 | 10 mm × 24 |
B2 | 12 mm × 24 |
B3 | 13 mm × 24 |
B4 | 15 mm × 16 |
B5 | 16 mm × 16 |
B6 | 19 mm × 12 |
B7 | 20 mm × 12 |
B8 | 26 mm × 8 |
B9 | 28 mm × 4 |
B10 | 40 mm × 3 |
B11 | 1.5 ml centrifuge tube × 24 |
B12 | 2.0 ml centrifuge tube × 24 |
Frequently asked questions For Sample Concentrator
1. What type of samples can be processed with Sample Concentrator LB-14SC?
Sample Concentrator LB-14SC is suitable for biological, pharmaceutical, food, and environmental samples that require solvent evaporation without oxygen exposure.
2. Can Sample Concentrator LB-14SC handle high-temperature applications?
Yes, Sample Concentrator LB-14SC operates within a temperature range of 0 °C to 160 °C. This makes it suitable for processing heat-stable solvents and compounds.
3. How many samples can Sample Concentrator LB-14SC process at once?
Labotronics Sample Concentrator LB-14SC can process up to 24 samples simultaneously depending on the block configuration. This makes it suitable for both small and medium-throughput laboratories.
4. How durable is Sample Concentrator LB-14SC for routine laboratory use?
Our Sample Concentrator LB-14SC is built with durable materials and a reliable block system. It withstands daily laboratory use while maintaining consistent performance.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Number of Blocks | 2 |
| Nitrogen Gas Flow Rate | 23L/min |
| Nitrogen Gas Pressure | 0.02Mpa (Gas needle≤16pcs) 0.05Mpa (Gas needle>16pcs) |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5℃ to 160℃ |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Needle length | 80 mm |
| Heat up time | ≤ 30 mins (40 °C to 150 °C) |
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Heat up time | ≤ 30 mins (40 °C to 150 °C) |
| Power | 400 W |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Needle Length | 150 mm |
| Temperature Control Range | RT+5℃ to 160℃ |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 200 kPa |
| Tube size | 10 to 29 mm (liquid volume 1 ml to 50 ml) |
| Sample position | 12 positions |
| Heat up time | ≤ 30 mins (40 °C to 99 °C) |
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.1 Mpa |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Power | 500 W |
| Number of Blocks | 2 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5℃ to 160℃ |
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.02 MPa (Gas needle ≤ 16 pcs) 0.05 MPa (Gas needle > 16 pcs) |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Power | 500 W |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Needle length | 150 mm |
| Heat up time | ≤ 30 mins (40 °C to 150 °C) |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.02 MPa (Gas needle ≤ 16 pcs) 0.05 MPa (Gas needle > 16 pcs) |
| Needle length | 150 mm |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5 ℃ to 160 ℃ |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.1 MPa |
| Needle length | 150 mm |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.05 Mpa |
| Temperature Control Range | RT+5℃ to 160℃ |
| Temperature Accuracy | ≤±0.5 ℃ (at 40 ℃) ≤±1 ℃ (at 120 ℃) |