$ 2100
Download CatalogSpecifications
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.1 Mpa |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Power | 500 W |
| Needle length | 150 mm |
| Temperature control range | RT 5 °C to 160 °C |
| Time range | 1 min to 99 hrs and 59 mins |
| Temperature uniformity | ≤ ± 0.5 °C |
| 40 °C Temperature accuracy | ± 0.5 °C |
| 120 °C Temperature accuracy | ± 1 °C |
| Voltage | AC 220 V, 50 Hz AC 110 V, 60 Hz |
| Dimensions (W × D × H) | 260 × 220 × 475 mm |
| Weight | 7.5 kgs |
Features
Applications
Used in drug screening, sample preparation analysis, hormone assays, chromatographic analysis, scintillation counting, commodity inspection, etc.Optional Blocks
| Block type | Block diameter | Block capacity |
|---|---|---|
| B01 | 10 mm | 12 |
| B02 | 12 mm | 12 |
| B03 | 13 mm | 12 |
| B04 | 15 mm | 12 |
| B05 | 16 mm | 12 |
| B06 | 19 mm | 12 |
| B07 | 20 mm | 12 |
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Needle length | 150 mm |
| Heat up time | ≤ 30 mins (40 °C to 150 °C) |
| Number of Blocks | 2 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5℃ to 160℃ |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 200 kPa |
| Tube size | 10 to 29 mm (liquid volume 1 ml to 50 ml) |
| Sample position | 12 positions |
| Heat up time | ≤ 30 mins (40 °C to 99 °C) |
| Number of Blocks | 2 |
| Nitrogen Gas Flow Rate | 23L/min |
| Nitrogen Gas Pressure | 0.02Mpa (Gas needle≤16pcs) 0.05Mpa (Gas needle>16pcs) |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5℃ to 160℃ |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.1 MPa |
| Needle length | 150 mm |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Needle length | 80 mm |
| Heat up time | ≤ 30 mins (40 °C to 150 °C) |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.02 MPa (Gas needle ≤ 16 pcs) 0.05 MPa (Gas needle > 16 pcs) |
| Needle length | 150 mm |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.02 MPa (Gas needle ≤ 16 pcs) 0.05 MPa (Gas needle > 16 pcs) |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Power | 500 W |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5 ℃ to 160 ℃ |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Needle Length | 150 mm |
| Temperature Control Range | RT+5℃ to 160℃ |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.05 Mpa |
| Temperature Control Range | RT+5℃ to 160℃ |
| Temperature Accuracy | ≤±0.5 ℃ (at 40 ℃) ≤±1 ℃ (at 120 ℃) |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.02Mpa (Gas needle≤16pcs) 0.05Mpa (Gas needle>16pcs) |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5℃ to 160℃ |
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Heat up time | ≤ 30 mins (40 °C to 150 °C) |
| Power | 400 W |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534