Download CatalogSpecifications
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 200 kPa |
| Tube size | 10 to 29 mm (liquid volume 1 ml to 50 ml) |
| Sample position | 12 positions |
| Heat up time | ≤ 30 mins (40 °C to 99 °C) |
| Power | 1000 W |
| Gas joint diameter | 8 mm |
| Temperature range | RT 5 °C to 99 °C |
| Time range | 1 min to 99 hrs and 59 mins |
| Temperature uniformity | ≤ ± 1 °C at 60 °C |
| Temperature accuracy | ≤ ± 1 °C |
| Maximum vertical travel | 200 mm |
| Fuse | 250 V 8A, 5 × 20 |
| Dimension (W × D × H) | 390 × 300 × 850 mm |
| Weight | 10 kgs |
Features
Applications
Used in drug screening, sample preparation analysis, hormone assays, chromatographic analysis, scintillation counting, commodity inspection, etc.Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Needle length | 80 mm |
| Heat up time | ≤ 30 mins (40 °C to 150 °C) |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Needle Length | 150 mm |
| Temperature Control Range | RT+5℃ to 160℃ |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.1 MPa |
| Needle length | 150 mm |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Number of Blocks | 2 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5℃ to 160℃ |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5 ℃ to 160 ℃ |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.05 Mpa |
| Temperature Control Range | RT+5℃ to 160℃ |
| Temperature Accuracy | ≤±0.5 ℃ (at 40 ℃) ≤±1 ℃ (at 120 ℃) |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.02 MPa (Gas needle ≤ 16 pcs) 0.05 MPa (Gas needle > 16 pcs) |
| Needle length | 150 mm |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Heat up time | ≤ 30 mins (40 °C to 150 °C) |
| Power | 400 W |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.02Mpa (Gas needle≤16pcs) 0.05Mpa (Gas needle>16pcs) |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5℃ to 160℃ |
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.02 MPa (Gas needle ≤ 16 pcs) 0.05 MPa (Gas needle > 16 pcs) |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Power | 500 W |
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.1 Mpa |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Power | 500 W |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Needle length | 150 mm |
| Heat up time | ≤ 30 mins (40 °C to 150 °C) |
| Number of Blocks | 2 |
| Nitrogen Gas Flow Rate | 23L/min |
| Nitrogen Gas Pressure | 0.02Mpa (Gas needle≤16pcs) 0.05Mpa (Gas needle>16pcs) |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5℃ to 160℃ |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections
Best Seller
Quick Links
Copyright © Labotronics Scientific 2026