Sample Concentrator LB-15SC provides a temperature range of 0 °C to 160 °C for efficient solvent removal. It integrates PID fuzzy control technology, delivering consistent heating and uniform processing. It supports individual nitrogen flow for each sample, ensuring efficient handling of multiple samples simultaneously. Our sample concentrator includes a microprocessor control for precise and reliable operation.
$ 1650
Download CatalogSpecifications
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Temperature Range | 0 °C to 160 °C |
| Temperature Control Range | RT+5 ℃ to 160 ℃ |
| Temperature Accuracy | ≤±0.5 ℃ (at 40 ℃) ≤±1 ℃ (at 120 ℃) |
| Temperature Uniformity | ≤±0.5 ℃ |
| Display Accuracy | 0.1 °C |
| Heating Time | ≤ 15 mins (25 °C to 160 °C) |
| Timing Range | 1min to 99mins 59secs or Continuous (∞) |
| Maximum Vertical Movement | 200 mm |
| Power Consumption | 300 W |
| Power Supply | AC220/110V, 50/60Hz |
| Dimensions (W × D × H) | 260 × 220 × 475 mm |
| Weight | 6 kg |
Features
Adjustable nitrogen airflow
Quick thermal response
Automatic fault detection
Overheat protection system
Temperature calibration function
Applications
Sample Concentrator LB-15SC is ideal for use in laboratories, research centers, and quality control facilities for residue analysis, food testing, and environmental monitoring.
Optional Blocks
Block No | Block Capacity |
B1 | 10 mm × 12 |
B2 | 12 mm × 12 |
B3 | 13 mm × 12 |
B4 | 15 mm × 12 |
B5 | 16 mm × 12 |
B6 | 19 mm × 12 |
B7 | 20 mm × 12 |
Frequently asked questions For
1. How does Sample Concentrator LB-15SC ensure accurate temperature control?
Labotronics Sample Concentrator LB-15SC integrates PID fuzzy control and a microprocessor system, maintaining accuracy within ±0.5 °C at 40 °C and ±1 °C at 120 °C.
2. What makes Sample Concentrator LB-15SC efficient for solvent removal?
Sample Concentrator LB-15SC combines rapid heating, adjustable nitrogen flow, and uniform temperature distribution. This ensures faster evaporation without sample loss, making it reliable for high-throughput labs.
3. Does Sample Concentrator LB-15SC provide safety features?
Yes, Sample Concentrator LB-15SC is equipped with an overheat protection system and automatic fault detection, ensuring safe and reliable operation.
4. How does Sample Concentrator LB-15SC manage nitrogen gas distribution?
Sample Concentrator LB-15SC provides independent nitrogen flow to each sample position. This feature allows efficient solvent removal and prevents cross-contamination between samples.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Needle length | 80 mm |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Needle length | 150 mm |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.02 MPa (Gas needle ≤ 16 pcs) 0.05 MPa (Gas needle > 16 pcs) |
| Needle length | 150 mm |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 200 kPa |
| Tube size | 10 to 29 mm (liquid volume 1 ml to 50 ml) |
| Sample position | 12 positions |
| Number of Blocks | 2 |
| Nitrogen Gas Flow Rate | 23L/min |
| Nitrogen Gas Pressure | 0.02Mpa (Gas needle≤16pcs) 0.05Mpa (Gas needle>16pcs) |
| Temperature Range | 0 °C to 160 °C |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.02Mpa (Gas needle≤16pcs) 0.05Mpa (Gas needle>16pcs) |
| Temperature Range | 0 °C to 160 °C |
| Number of Blocks | 2 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Temperature Range | 0 °C to 160 °C |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.1Mpa |
| Needle Length | 150 mm |
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 330 ml / min |
| Nitrogen gas pressure | 33 kPa to 69 kPa |
| Heat up time | ≤ 30 mins (40 °C to 150 °C) |
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.1 Mpa |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Number of Blocks | 1 |
| Nitrogen Gas Flow Rate | 15L/min |
| Nitrogen Gas Pressure | 0.05 Mpa |
| Temperature Control Range | RT+5℃ to 160℃ |
| Number of Blocks | 2 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.02 MPa (Gas needle ≤ 16 pcs) 0.05 MPa (Gas needle > 16 pcs) |
| Heat up time | ≤ 15 mins (25 °C to 160 °C) |
| Number of Blocks | 1 |
| Nitrogen gas flow rate | 15 L / min |
| Nitrogen gas pressure | 0.1 MPa |
| Needle length | 150 mm |