Temperature Test Chamber LB-28TTC operates within a temperature range of -40 to +150°C and has a testing capacity of 500 liters. It includes an independent heating system for consistent temperature control. It utilizes an advanced refrigeration system for efficient cooling. Our temperature test chamber features a programmable touchscreen controller for real-time tracking of safety alarms and temperature levels.

$ 11137.5

Download Catalog

Specifications

Capacity 500L
Temperature Range -40 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Heating Rate 2.0 to 3.0°C/min
Cooling Rate 0.7 to 1.0°C/min
Refrigerant R404A/R23
Refrigeration System Unit cooling mode / Dual cooling mode
Heating System NiCr heater, independent system
Circulation System Single cycle, long axis, and stainless-steel multi-leaf type centrifuge fan
Display 7-inch touch screen
Interior Anti-corrosion SUS#304 mirror stainless steel
Exterior Reinforced Steel plate with electrostatic spraying
Insulation Superfine fiberglass wool/polyurethane foam
Power Supply 220V 50/60Hz, 380V 50/60Hz or customized
Inner Dimension (W × D × H) 800 × 700 × 900 mm
Outer Dimension (W × D × H) 1350 × 1300 × 2200 mm
Gross Weight 590 kg

Features

  • User-friendly interface
  • Customizable settings
  • Multi-leaf centrifugal fan
  • Low noise operation
  • Durable construction
  • Audible signal alarm

Applications

Temperature Test Chamber LB-28TTC is used for testing the temperature resistance and stability of materials, components, and products. It's widely used in industries like electronics, automotive, aerospace, and R&D.
Temperature Test Chamber LB-28TTC Banner
Temperature Test Chamber LB-28TTC Banner

Get Quote

Frequently asked questions For Temperature Test Chamber

1. How does LB-28TTC improve product reliability?

Our LB-28TTC chamber helps to detect defects, assess material behavior by replicating real-world thermal conditions, and ensure consistent product performance before market release.

2. Can LB-28TTC simulate both extreme cold and heat?

Yes, LB-28TTC can replicate a wide range of temperature conditions, making it ideal for environmental testing, thermal stress analysis, and material evaluation.

3. How does LB-28TTC enhance laboratory workflow efficiency?

Labotronics LB-28TTC minimizes manual intervention and enables high-throughput testing with programmable test cycles, rapid temperature stabilization, and a large chamber capacity.

4. How does LB-28TTC support accelerated product life testing?

By simulating extreme and repetitive thermal cycles, LB-28TTC helps identify product weaknesses and predict long-term performance quickly.

5. What is a Temperature Test Chamber used for?

A Temperature Test Chamber is used to simulate specific temperature conditions to test the durability, stability, and performance of products or materials in industries like electronics, automotive, aerospace, and pharmaceuticals.

6. How is temperature stability maintained during testing?

The chamber is equipped with precise control systems and insulated walls to ensure consistent temperature levels throughout the testing cycle.

7. How easy is it to operate the chamber with gloves on?

The user interface is designed to be glove-friendly, allowing operators to adjust settings and monitor tests without removing protective equipment.

8. Can the Labotronics test chamber handle both high and low temperatures?

Yes, Our Temperature Test Chambers can simulate a wide range of conditions, from extreme cold to high heat, making them ideal for various testing requirements.

Still have questions?

If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!

Temperature Test Chamber

Capacity 500L
Temperature Range 0 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 100L
Temperature Range -20 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 1000L
Temperature Range -20 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 150L
Temperature Range -20 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 50L
Temperature Range -40 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 50L
Temperature Range -20 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 800L
Temperature Range -20 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 50L
Temperature Range -70 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 100L
Temperature Range -40 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 500L
Temperature Range -20 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 1000L
Temperature Range 0 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 1000L
Temperature Range -40 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 150L
Temperature Range -70 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 800L
Temperature Range -70 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C
Capacity 150L
Temperature Range -40 to +150°C
Temperature Fluctuation ≤ ±0.5°C
Temperature Uniformity ≤ 2.0°C