Vertical Autoclave LB-12VCA offers a 50 L capacity and operates within a temperature range of 105°C to 136°C, ensuring effective and reliable sterilization. It incorporates a counter-pressure protection mechanism that prevents deformation or damage to sensitive loads. It includes pre-programmed sterilization cycles, allowing customizable operation. The autoclave features a high-resolution touchscreen display for clear visualization of operating parameters.
$ 3687.5
Download CatalogSpecifications
| Capacity | 50 L |
| Chamber Dimension | Φ316 × 667 mm |
| Temperature Range | 105 to 136℃ |
| Maximum Working Temperature | 136℃ |
| Temperature Accuracy | 0.1℃ |
| Temperature Uniformity | ≤ ±0.5℃ |
| Maximum Working Pressure | 0.23Mpa |
| Design Pressure | 0.3Mpa |
| Design Temperature | 150℃ |
| Display | Touchscreen |
| Power Supply | AC220-240V,50/60Hz |
| Product Dimension | 476 × 636 × 990 mm |
| Packaging Dimension | 700 × 680 × 1140 mm |
| Net Weight | 86 kg |
| Gross Weight | 102 kg |
Features
Counter-pressure protection
Uniform heat distribution
Air cooling system
Over-temperature protection
Atmospheric pressure correction
Cycle-end buzzer alert
Automatic sterilization cycle
Anti-dry heating alarm
Standard Accessories
Optional Accessories
30L Air Compressor
Applications
Vertical Autoclave LB-12VCA is used for high-pressure steam sterilization of liquid media, glassware, and other laboratory instruments. It is widely applied in laboratories, research institutes, pharmaceutical industries, and medical facilities.
Frequently asked questions For Vertical Autoclave
1. What is the primary purpose of a Labotronics vertical autoclave?
Labotronics vertical autoclave is designed for high-efficiency steam sterilization, ensuring complete decontamination of laboratory and clinical instruments, media, and materials.
2. How does microcomputer control technology benefit Labotronics vertical autoclaves?
Labotronics vertical autoclaves use advanced microcomputer control to automate all sterilization phases, providing consistent performance with minimal operator intervention.
3. What makes the touchscreen interface on Labotronics vertical autoclaves useful?
Labotronics vertical autoclaves feature a user-friendly touchscreen interface that allows easy monitoring of temperature, pressure, and cycle progress for precise operation.
4. Do Labotronics vertical autoclaves ensure safety during operation?
Yes. Labotronics vertical autoclaves are equipped with multiple safety features including overpressure protection and automatic steam exhaust, ensuring safe use for operators.
5. How do Labotronics vertical autoclaves maintain temperature accuracy?
Labotronics vertical autoclaves provide uniform temperature distribution with precision controls, guaranteeing consistent sterilization performance across all loads.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Capacity | 75 L |
| Temperature Range | 0 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |
| Capacity | 35 L |
| Temperature Range | 105 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |
| Capacity | 50 L |
| Working Temperature Range | 105 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |
| Capacity | 35 L |
| Working Temperature Range | 105 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |
| Capacity | 80 L |
| Chamber Dimension | Φ386 × 700 mm |
| Temperature Range | 105 to 136℃ |
| Maximum Working Temperature | 136℃ |
| Temperature Accuracy | 0.1℃ |
| Capacity | 100 L |
| Temperature Range | 105 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |
| Capacity | 100 L |
| Temperature Range | 0 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |
| Capacity | 75 L |
| Working Temperature Range | 105 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |
| Capacity | 50 L |
| Temperature Range | 105 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |
| Capacity | 50 L |
| Temperature Range | 0 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |
| Capacity | 120 L |
| Maximum Working Temperature | 138°C |
| Sterilization Temperature Range | 105°C to 138°C |
| Maximum Working Pressure | 0.23 MPa |
| Design Pressure | - 0.1 to 0.3 MPa |
| Capacity | 100 L |
| Temperature Range | 105 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |
| Capacity | 150 L |
| Temperature Range | 105 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |
| Capacity | 100 L |
| Maximum Working Temperature | 136℃ |
| Sterilization Temperature Range | 105 to 136℃ |
| Maximum Working Pressure | 0.23 MPa |
| Design Pressure | 0.3 MPa |
| Capacity | 35 L |
| Temperature Range | 0 to 134 °C |
| Maximum Working Temperature | 134 °C |
| Temperature Uniformity | ≤ ± 1 °C |
| Working Pressure | 0.22 MPa |