XRF RoHS analyzer LB-10RA is a handheld analyzer designed for on-site analysis of lead, mercury, cadmium and other restricted toxic element concentration present in electronic equipments and consumer products. Built-in ultra-short light path design improves light element Mg, Al, Si, S and P excitation effect. Equipped with BOOST Si-pin detector and automated environmental parameter (temperature, dust and dark) regulation facilitates high accuracy analysis.
Buy Now Download CatalogSpecifications
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | Pb, Hg, Cd, Cr, Br and As |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Operating humidity | ≤ 90 % |
Pipe flow pressure | Adjustable |
Digital pulse processor | 80 MHz ADC digital pulse processor |
Heat dissipation system | T-shaped radiator |
Display panel | 4.3 inch industrial resistive touch screen |
Display brightness | Automated adjustment |
Memory capacity | 32 GB |
Data storage | 32 GB, 300,000 spectral data |
Battery life | 8 hours |
Dimensions ( W x H x D ) | 79 x 280 x 254 mm |
Weight ( with battery ) | 1.6 kgs |
Features
Applications
Used in petrochemical, metal, plastic, electronic, mining and automotive industry to test and identify the concentration of restricted toxic elements like cadmium, lead and mercury present in consumer goods, polymeric materials, plastic articles, packaging materials and electronic componentsDetector | BOOST Si-pin detector |
Detection range ( ppm ) | K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Hf, Ta, W, Au, Hg Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, W, Re, Pd, Au, Hg, Pb, Bi, Cs, Ba, Th and U |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | SDD detector |
Detection range ( ppm ) | Mg, Al, Si, P, S, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Zr, Nb, Mo, Rh, Pd, Ag, Cd, Sn, Sb, Hf, Ta, W, Re, Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | Fe, Co, Ni, Cu, Zn, Se, Ru, Rh, Pd, Ag, Cd, In, Ir, Pt, Au and Pb |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Zr, Nb, Mo, Rh, Pd, Ag, Cd, Sn, Sb, Hf, Ta, W, Re, Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | SDD detector |
Detection range ( ppm ) | Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, W, Au, Hg, Pb, Bi, Ba, Th, U, Sc, Cs, Te, Pd, Hf, Ta, Re, Ge Tl and I |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | SDD detector |
Detection range ( ppm ) | Mg, Al, Si, P, S, Cl ,K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Hf, Ta, W, Au, Hg, Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 ° C) |