XRF alloy analyzer LB-66AL is a handheld analyzer designed for analysis of the elemental composition of alloys. It determines the chemistry of a sample by measuring the fluorescent X-rays emitted when excited by a primary-ray source. The built-in library of 380 alloy types facilitates analysis of a wide range of alloy materials. Configured with SDD detector enabling high accuracy elemental analysis.
Buy Now Download CatalogSpecifications
Detector | SDD detector |
Detection range ( ppm ) | Mg, Al, Si, P, S, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Zr, Nb, Mo, Rh, Pd, Ag, Cd, Sn, Sb, Hf, Ta, W, Re, Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Operating humidity | ≤ 90 % |
Pipe flow pressure | Adjustable |
Digital pulse processor | 80 MHz ADC digital pulse processor |
Heat dissipation system | T-shaped radiator |
Display panel | 4.3 inch industrial resistive touch screen |
Display brightness | Automated adjustment |
Memory capacity | 32 GB |
Data storage | 32 GB, 300,000 spectral data |
Battery life | 8 hours |
Dimensions ( W x H x D ) | 79 x 280 x 254 mm |
Weight ( with battery ) | 1.6 kgs |
Features
Applications
Used in petrochemical industry, thermal power plant, nuclear power plant, hydroelectric power plant, metals and mining industries for alloy grade identification and analysis
What our customers say
Chris Mapesa
8 months ago
Suneil Dua
2 years ago
Ramunas Diliautas
1 year ago
Peipert Scott
2 years ago
Ethan James
2 months ago
Guillermo B. Moraga
2 years ago
Deeptendu Jena
1 year ago
MIRZA AFZAL ALI
3 years ago
Muhammad Ali Kifayat
1 year ago
Ahmad Hilal
2 years ago
Add a review
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | Pb, Hg, Cd, Cr, Br and As |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Zr, Nb, Mo, Rh, Pd, Ag, Cd, Sn, Sb, Hf, Ta, W, Re, Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | Fe, Co, Ni, Cu, Zn, Se, Ru, Rh, Pd, Ag, Cd, In, Ir, Pt, Au and Pb |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, W, Re, Pd, Au, Hg, Pb, Bi, Cs, Ba, Th and U |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Hf, Ta, W, Au, Hg Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | SDD detector |
Detection range ( ppm ) | Mg, Al, Si, P, S, Cl ,K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Hf, Ta, W, Au, Hg, Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 ° C) |
Detector | SDD detector |
Detection range ( ppm ) | Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, W, Au, Hg, Pb, Bi, Ba, Th, U, Sc, Cs, Te, Pd, Hf, Ta, Re, Ge Tl and I |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |