$ 35187.5
Download CatalogSpecifications
| Detector | SDD detector |
| Detection range ( ppm ) | Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, W, Au, Hg, Pb, Bi, Ba, Th, U, Sc, Cs, Te, Pd, Hf, Ta, Re, Ge Tl and I |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Pipe flow pressure | Adjustable |
| Digital pulse processor | 80 MHz ADC digital pulse processor |
| Heat dissipation system | T-shaped radiator |
| Display panel | 4.3 inch industrial resistive touch screen |
| Display brightness | Automated adjustment |
| Memory capacity | 32 GB |
| Data storage | 32 GB, 300,000 spectral data |
| Battery life | 8 hours |
| Dimensions ( W x H x D ) | 79 x 280 x 254 mm |
| Weight ( with battery ) | 1.6 kgs |
Features
Applications
Used for on-site environmental pollution assessment to test for the presence of toxic and hazardous heavy metals like arsenic, barium, cadmium, chromium, lead, mercury, selenium and silver as part of environmental remediation efforts, regulatory compliance and to ensure product safetyStill have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Detector | BOOST Si-pin detector |
| Detection range ( ppm ) | K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Hf, Ta, W, Au, Hg Pb and Bi |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Detector | BOOST Si-pin detector |
| Detection range ( ppm ) | Pb, Hg, Cd, Cr, Br and As |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Detector | BOOST Si-pin detector |
| Detection range ( ppm ) | Fe, Co, Ni, Cu, Zn, Se, Ru, Rh, Pd, Ag, Cd, In, Ir, Pt, Au and Pb |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Detector | BOOST Si-pin detector |
| Detection range ( ppm ) | Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Zr, Nb, Mo, Rh, Pd, Ag, Cd, Sn, Sb, Hf, Ta, W, Re, Pb and Bi |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Detector | SDD detector |
| Detection range ( ppm ) | Mg, Al, Si, P, S, Cl ,K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Hf, Ta, W, Au, Hg, Pb and Bi |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 ° C) |
| Operating humidity | ≤ 90 % |
| Detector | BOOST Si-pin detector |
| Detection range ( ppm ) | K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, W, Re, Pd, Au, Hg, Pb, Bi, Cs, Ba, Th and U |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Detector | SDD detector |
| Detection range ( ppm ) | Mg, Al, Si, P, S, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Zr, Nb, Mo, Rh, Pd, Ag, Cd, Sn, Sb, Hf, Ta, W, Re, Pb and Bi |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections
Best Seller
Quick Links