


$ 26187.5
Download CatalogSpecifications
| Detector | BOOST Si-pin detector |
| Detection range ( ppm ) | Pb, Hg, Cd, Cr, Br and As |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Pipe flow pressure | Adjustable |
| Digital pulse processor | 80 MHz ADC digital pulse processor |
| Heat dissipation system | T-shaped radiator |
| Display panel | 4.3 inch industrial resistive touch screen |
| Display brightness | Automated adjustment |
| Memory capacity | 32 GB |
| Data storage | 32 GB, 300,000 spectral data |
| Battery life | 8 hours |
| Dimensions ( W x H x D ) | 79 x 280 x 254 mm |
| Weight ( with battery ) | 1.6 kgs |
Features
Applications
Used in petrochemical, metal, plastic, electronic, mining and automotive industry to test and identify the concentration of restricted toxic elements like cadmium, lead and mercury present in consumer goods, polymeric materials, plastic articles, packaging materials and electronic componentsStill have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Detector | BOOST Si-pin detector |
| Detection range ( ppm ) | Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Zr, Nb, Mo, Rh, Pd, Ag, Cd, Sn, Sb, Hf, Ta, W, Re, Pb and Bi |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Detector | SDD detector |
| Detection range ( ppm ) | Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, W, Au, Hg, Pb, Bi, Ba, Th, U, Sc, Cs, Te, Pd, Hf, Ta, Re, Ge Tl and I |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Detector | SDD detector |
| Detection range ( ppm ) | Mg, Al, Si, P, S, Cl ,K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Hf, Ta, W, Au, Hg, Pb and Bi |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 ° C) |
| Operating humidity | ≤ 90 % |
| Detector | BOOST Si-pin detector |
| Detection range ( ppm ) | Fe, Co, Ni, Cu, Zn, Se, Ru, Rh, Pd, Ag, Cd, In, Ir, Pt, Au and Pb |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Detector | BOOST Si-pin detector |
| Detection range ( ppm ) | K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Hf, Ta, W, Au, Hg Pb and Bi |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Detector | BOOST Si-pin detector |
| Detection range ( ppm ) | K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, W, Re, Pd, Au, Hg, Pb, Bi, Cs, Ba, Th and U |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
| Detector | SDD detector |
| Detection range ( ppm ) | Mg, Al, Si, P, S, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Zr, Nb, Mo, Rh, Pd, Ag, Cd, Sn, Sb, Hf, Ta, W, Re, Pb and Bi |
| Excitation source ( standard ) | 50 kV / 200 µA Ag target |
| Operating temperature | ( -20 °C to 50 °C ) |
| Operating humidity | ≤ 90 % |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections
Best Seller
Quick Links
Copyright © Labotronics Scientific 2026