Muffle Furnace LB-14MFF operates at a temperature range of up to 1400℃ and offers a 1L capacity, ensuring precise material testing. It integrates an Al₂O₃ ceramic fiber refractory chamber, providing excellent thermal insulation. It features a built-in voltmeter and ammeter for real-time monitoring of electrical parameters. Our muffle furnace includes an S-type thermocouple for enhanced operational safety and temperature reliability.
$ 2825
Download CatalogSpecifications
| Capacity | 1L |
| Working Temperature Range | 0 to 1300℃ |
| Maximum Temperature | 1400℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 20℃/min |
| Heating Element | SiC heating element |
| Thermocouple | S type |
| Temperature Controller | Intelligent PID controller |
| Chamber Material | 1600°C Al₂O₃ ceramic fiber refractory chamber |
| Power Consumption | 2 kW |
| Power Supply | 220V, Single Phase (1P) |
| Internal Dimension (D × W × H) | 100 × 100 × 100 mm |
| Packaging Dimension | 580 × 455 × 815 mm |
| Weight | 53 kg |
Features
Over-temperature protection
Dual-side heating
PID temperature control
30-segment programming
User-friendly interface
Durable construction
Applications
Muffle Furnace LB-14MFF is used for high-temperature material testing, heat treatment, and sintering processes. It is widely applied in research laboratories, metallurgy, ceramics, electronics, and quality control industries.
Frequently asked questions For Muffle Furnace
1. What are muffle furnaces used for?
Our muffle furnaces are used for high-temperature heating in laboratories and industrial settings. It’s ideal for applications such as ashing, heat treatment, material testing, and ceramics processing.
2. Does Labotronics offer different models of muffle furnaces?
Yes, Labotronics offers a wide range of muffle furnace models with different chamber sizes, temperature capacities, and control options to accommodate various laboratory and industrial requirements.
3. Are your muffle furnaces easy to operate?
Absolutely. Labotronics furnaces are designed with user-friendly digital controllers for precise temperature control and simple operation.
4. What safety features are included in your muffle furnaces?
Labotronics furnaces typically include features such as over-temperature protection, ceramic insulation, and door safety switches.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Capacity | 27 L |
| Working Temperature | 1100 ℃ |
| Maximum Temperature | 1200 ℃ |
| Temperature Control Accuracy | ± 1 ℃ |
| Heating Rate | 0 to 20 ℃/min |
| Maximum Temperature | 1100℃ |
| Temperature Accuracy | ±2℃ |
| Heating Rate | ≤ 70℃/min |
| Heating Element | Dental silicon carbide rods |
| Program Stage | 30 stages |
| Capacity | 12 L |
| Working Temperature Range | 0 to 1100℃ |
| Maximum Temperature | 1200℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 30℃/min (Adjustable) |
| Capacity | 1 L |
| Working Temperature Range | 0 to 1600℃ |
| Maximum Temperature | 1700℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 10℃/min (Adjustable) |
| Maximum temperature | 1200 ℃ |
| Working temperature | 1100 ℃ |
| Temperature controller | Digital PID controller (Program: 30 segment) |
| Temperature control accuracy | ± 1℃ |
| Heating | Resistance wire |
| Capacity | 36 L |
| Working Temperature Range | 0 to 1600℃ |
| Maximum Temperature | 1700℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 10℃/min (Adjustable) |
| Capacity | 36 L |
| Working Temperature Range | 0 to 1100℃ |
| Maximum Temperature | 1200℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 30℃/min (Adjustable) |
| Capacity | 12 L |
| Working Temperature Range | 0 to 1300℃ |
| Maximum Temperature | 1400℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 20℃/min |
| Capacity | 12 L |
| Working Temperature Range | 0 to 1600℃ |
| Maximum Temperature | 1700℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 10℃/min (Adjustable) |
| Capacity | 4.5 L |
| Working Temperature Range | 0 to 1600℃ |
| Maximum Temperature | 1700℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 10℃/min (Adjustable) |
| Capacity | 4.5L |
| Working Temperature Range | 0 to 1300℃ |
| Maximum Temperature | 1400℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 20℃/min |
| Capacity | 36 L |
| Working Temperature Range | 0 to 1300℃ |
| Maximum Temperature | 1400℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 20℃/min |
| Capacity | 4.5 L |
| Working Temperature Range | 0 to 1100℃ |
| Maximum Temperature | 1200℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 30℃/min (Adjustable) |
| Capacity | 1 L |
| Working Temperature Range | 0 to 1100℃ |
| Maximum Temperature | 1200℃ |
| Temperature Precision | ±1℃ |
| Heating Rate | 0 to 30℃/min (Adjustable) |