Volume Range

Increment

Test Volume

Accuracy Error

Adjustable Volume Micro Pipette LB-10AVP

Adjustable Volume Micro Pipette LB-10AVP

    Volume Range 0.1 to 2.5 μL
    Increment 0.05 μL
    Test Volume 2.5 μL, 1.25 μL, 0.25 μL
    Accuracy Error 0.0625μL, 0.0375μL, 0.03μL
Adjustable Volume Micro Pipette LB-11AVP

Adjustable Volume Micro Pipette LB-11AVP

    Volume Range 0.5 to 10μL
    Increment 0.1μL
    Test Volume 10 μL, 5 μL, 1 μL
    Accuracy Error 0.1μL, 0.075μL, 0.025μL
Adjustable Volume Micro Pipette LB-12AVP

Adjustable Volume Micro Pipette LB-12AVP

    Volume Range 2 to 20μL
    Increment 0.5μL
    Test Volume 20 μL, 10 μL, 2 μL
    Accuracy Error 0.18μL, 0.12μL, 0.06μL
Adjustable Volume Micro Pipette LB-13AVP
Adjustable Volume Micro Pipette LB-13AVP
    Volume Range 5 to 50μL
    Increment 0.5μL
    Test Volume 50 μL, 25 μL, 5 μL
    Accuracy Error 0.3μL, 0.225μL, 0.1μL
Adjustable Volume Micro Pipette LB-14AVP
Adjustable Volume Micro Pipette LB-14AVP
    Volume Range 10 to 100μL
    Increment 1μL
    Test Volume 100 μL, 50 μL, 10 μL
    Accuracy Error 0.8μL, 0.5μL, 0.3μL
Adjustable Volume Micro Pipette LB-15AVP

Adjustable Volume Micro Pipette LB-15AVP

    Volume Range 20 to 200μL
    Increment 1μL
    Test Volume 200 μL, 100 μL, 20 μL
    Accuracy Error 1.2μL, 0.8μL, 0.6μL
Adjustable Volume Micro Pipette LB-16AVP

Adjustable Volume Micro Pipette LB-16AVP

    Volume Range 50 to 200μL
    Increment 1μL
    Test Volume 200 μL, 100 μL, 50 μL
    Accuracy Error 1.2μL, 0.8μL, 0.5μL
Adjustable Volume Micro Pipette LB-17AVP

Adjustable Volume Micro Pipette LB-17AVP

    Volume Range 100 to 1000μL
    Increment 5μL
    Test Volume 1000 μL, 500 μL, 100 μL
    Accuracy Error 6μL, 3.5μL, 2μL
Adjustable Volume Micro Pipette LB-18AVP
Adjustable Volume Micro Pipette LB-18AVP
    Volume Range 200 to 1000μL
    Increment 5μL
    Test Volume 1000 μL, 500 μL, 200 μL
    Accuracy Error 6μL, 3.5μL, 1.8μL
Adjustable Volume Micro Pipette LB-19AVP
Adjustable Volume Micro Pipette LB-19AVP
    Volume range 1000 to 5000 μL
    Increment 50 μL
    Test volume 5000 μL, 2500 μL, 1000 μL
    Accuracy Error ± 25 μL, ± 15 μL, ± 7 μL
    ± 0.50 %, ± 0.60 %, ± 0.70 %
Adjustable Volume Micro Pipette LB-20AVP

Adjustable Volume Micro Pipette LB-20AVP

    Volume range 2000 to 10000 μL
    Increment 100 μL
    Test volume 10000 μL, 5000 μL, 2000 μL
    Accuracy Error ± 60 μL, ± 60 μL, ± 60 μL
    ± 0.60 %, ± 1.20 %, ± 3.00 %

Frequently asked questions For Adjustable Volume Micro Pipette

1. What measurement range do they offer?

Ans. Our pipettes offer a wide measurement range from 0.1 µL to 10 mL, enabling flexibility for handling both very small and larger liquid volumes across different laboratory procedures.

2. How do these pipettes help prevent contamination?

Ans. Our pipettes are designed with touch-free tip ejection systems and universal tip compatibility. Regular calibration and secure tip fit help minimize the risk of cross-contamination, ensuring clean and reliable results.

3. Are these pipettes easy to calibrate and maintain?

Ans. Yes, they come with easily accessible calibration ports and clear maintenance guidelines, allowing users to perform quick recalibrations and routine care to maintain long-term accuracy.

4. How do these pipettes improve workflow efficiency?

Ans. With fast and smooth aspirate/dispense action and marked volume indicators, our pipettes help streamline repetitive lab tasks, enhancing productivity and sample throughput.

5. How durable and reliable are these pipettes?

Ans. We build our pipettes from chemical-resistant materials and incorporate robust internal mechanisms, ensuring consistent performance, minimal drift, and long-term reliability in demanding lab environments.

Still have questions?

If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!


WhatsApp
×

Get Quotation

Copyright © Labotronics Scientific 2025