Measurement range | 0.0 ~ 199.9 µs/cm 200 µs/cm ~ 1999 µs/cm 2.0 µs/cm ~ 19.99 ms/cm 20 µs/cm ~ 199.9 ms/cm |
Temperature compensation | 10 °C ~ 50 °C ( automatic ) |
Resolution | 0.1/1µs/cm 0.01/0.1ms/cm |
Accuracy ( electrode ) | ± 1 % FS |
Parameters | pH/ EC/ ISE/ Temp. (mV/ ORP/ pX/ Resistivity/ TDS /Sal.) | ||||||||||||||
pH |
|
||||||||||||||
mV |
|
||||||||||||||
pX |
|
Measurement range | 0 ~ 200 |
Minimum value | 0.1 |
Error | ± 6 % ( ± 2 % F.S ) |
Repeatability | ≤ 0.8 % |
Measurement range | 0 ~ 10 mg/L |
Resolution | 0.01 mg/L |
Repeatability | 0.01 |
Error | ± 5 % FS + 1 |
Measurement range | 0 ~ 10 mg/L |
Resolution | 0.01 mg/L |
Repeatability | 0.01 |
Error | ± 5 % FS + 1 |
Number of sample | 8 (Ø 42 mm) |
Dimensions | 350 × 750 × 370 mm |
Power | 1000 W |
Temperature | 5 °C to 200 °C |
Measurement range | 0 ~ 2500 mg/L |
Temperature | 0 °C ~ 50 °C |
Accuracy ( at 0.1 °C ) | ± 2 mg/L |
Resolution | 1 mg/L |
Measuring range | ± 1999 mV |
Accuracy | ± 5 mV |
Temperature | 0 °C ~ 50 °C |
Resolution |
Measurement range | 0 ~ 100 0 ~ 200 |
Calibration point | 4 |
Minimum value | 0.01 0.1 |
Repeatability | ≤ 0.5 % |
Measurement range | 0.005 ~ 50.0 NTU 1 ~ 200 NTU |
Allowable error of indication | ≤ ± 8 % |
Receiving element | Silicon photocell |
Light source | Tungsten halogen lamp 6 V, 10 W |
TDS measuring range | 0 ~ 2500 ppm |
EC measuring range | |
Temperature range | 0 °C ~ 50 °C |
Resolution | 2 ppm |
Measurement range | 0.0 ~ 199.9 µs/cm 200 µs/cm ~ 1999 µs/cm 2.0 µs/cm ~ 19.99 ms/cm 20 µs/cm ~ 199.9 ms/cm |
Temperature compensation | 10 °C ~ 50 °C ( manual ) |
Resolution | 0.1/1µs/cm 0.01/0.1ms/cm |
Accuracy ( electrode ) | ± 1 % FS |
Measurement range | 0 ~ 100 100 ~ 200 |
Minimum value | 0.01 0.1 |
Error | ± 6 % ( ± 2 % F.S ) |
Repeatability | ≤ 0.8 % |
Number of sample | 12 (Ø 42 mm) |
Dimensions | 360 × 750 × 430 mm |
Power | 1500 W |
Temperature | 5 °C to 200 °C |
Measurement range | 0 ~ 9999 mg/L |
Temperature | 0 °C ~ 50 °C |
Accuracy ( at 0.1 °C ) | ± 2 mg/L |
Resolution | 1 mg/L |
Measuring range | -1200 mV ~ 1200 mV |
Accuracy | ± 2 mV |
Temperature | 0 °C ~ 50 °C |
Resolution | 1 mV |
Measurement range | 0 ~ 100 100 ~ 400 |
Calibration point | 5 |
Minimum value | 0.01 0.1 |
Repeatability | ≤ 0.5 % |
Measurement range | 0.005 ~ 50.0 NTU 1 ~ 200 NTU 201 ~2000 NTU |
Allowable error of indication | 0 ~ 200 NTU: ≤ ± 8 % 201 ~ 200 NTU: ≤ ± 6 % |
Receiving element | Silicon photocell |
Light source | Tungsten halogen lamp 6 V, 10 W |
TDS measuring range | 0 ~ 9999 ppm |
EC measuring range | |
Temperature range | 0 °C ~ 50 °C |
Resolution | 10 ppm |
Measurement range | 0.0 ~ 2 × 105 µs/cm |
Temperature compensation | 15 °C ~ 35 °C ( manual ) |
Resolution | |
Accuracy ( electrode ) | ± 1 % FS |
Measurement range | 0 ~ 400 |
Minimum value | 0.01 0.1 |
Error | ± 6 % ( ± 2 % F.S ) |
Repeatability | ≤ 0.8 % |
Number of sample | 20 (Ø 42 mm) |
Dimensions | 420 × 750 × 480 mm |
Power | 2000 W |
Temperature | 5 °C to 200 °C |
Measurement range | 0 ~ 300 % |
Temperature | 0 °C ~ 50 °C |
Accuracy ( at 0.1 °C ) | ± 0.2 % |
Resolution | 0.02 |
Measurement range | 0 ~ 100 100 ~ 500 |
Calibration point | 6 |
Minimum value | 0.01 0.1 |
Repeatability | ≤ 0.5 % |
Measurement range | 0.005 ~ 50.0 NTU 1 ~ 200 NTU 201 ~2000 NTU 2001~4000 NTU |
Allowable error of indication | ≤ ± 6 % |
Receiving element | Silicon photocell |
Light source | Tungsten halogen lamp 6 V, 10 W |
Measurement range | 0 ~ 100 100 ~ 400 |
Minimum value | 0.01 0.1 |
Error | ± 6 % ( ± 2 % F.S ) |
Repeatability | ≤ 0.8 % |
Measurement range | 0 ~ 100 100 ~ 800 |
Calibration point | 6 |
Minimum value | 0.01 0.1 |
Repeatability | ≤ 0.5 % |
Measurement range | 0 ~ 800 |
Minimum value | 0.1 |
Error | ± 6 % ( ± 2 % F.S ) |
Repeatability | ≤ 0.8 % |
Measurement range | 0 ~ 100 100 ~ 1000 |
Calibration point | 7 |
Minimum value | 0.01 0.1 |
Repeatability | ≤ 0.5 % |
Measurement range | 0 ~ 100 100 ~ 800 |
Minimum value | 0.1 |
Error | ± 6 % ( ± 2 % F.S ) |
Repeatability | ≤ 0.8 % |
Measurement range | 0 ~ 200 |
Calibration point | 2 |
Minimum value | 0.1 |
Repeatability | ≤ 1 % |
Measurement range | 0 ~ 1000 |
Minimum value | 0.1 |
Error | ± 6 % ( ± 2 % F.S ) |
Repeatability | ≤ 0.8 % |
Measurement range | 0 ~ 1000 |
Calibration point | 7 |
Minimum value | 0.1 |
Repeatability | ≤ 1 % |
Type | Benchtop |
Principle method | Nephelometric principle with 90° detection |
Measuring Range | 0 to 20, 20 to 200, and 200 to 1000 NTU |
Auto-ranging | 0 to 1000 NTUs |
Measurement range | 0 ~ 20 |
Calibration point | |
Minimum value | 0.01 |
Repeatability | ≤ 1 % |
Measurement range | 0 ~ 20 0 ~ 200 |
Calibration point | |
Minimum value | 0.01 0.1 |
Repeatability | ≤ 1 % |
TDS measuring range | 0 ~ 5000 ppm |
EC measuring range | 0 ~ 999 µs/cm |
Temperature range | 0.1 °C ~ 80 °C |
Resolution |